Wall Pier Labeling

 A suggested pier labeling scheme for walls with openings is given in Figure 1:


Figure 1 - Pier labeling scheme

  • Additional information is available through Help > Documentation > Shear Wall Design > General Design Information.

    Note the following about the wall pier labeling scheme shown in Figure 1a:
  • Wall piers are always associated with the story level directly above them.
    Thus, in Figure 1a, the upper level wall piers are associated with the Roof
    level and the lower level wall piers are associated with the 2nd level. Because
    the wall piers are associated with story levels, wall pier labels can repeat
    at different levels, as shown in the figure.
  • When we refer to wall pier P1 at the Roof level in Figure 1a, we are referring
    to the pier across the entire width of the wall that is made up of the
    five area objects given the pier label P1. Similarly, pier P2 at the Roof level
    is made up of the two area objects to the left of the door opening.
  • Wall pier design is performed at the top and bottom of each pier. Thus, for
    wall pier P2 at the Roof level, design is performed at the top and bottom of
    the door opening. No design is performed near the midheight of the door
    opening because the design is done at the top and bottom of the wall pier,
    not the top and bottom of each area object that makes up the wall pier.
  • Wall pier forces are reported at the top and bottom of each pier. Thus, for
    wall pier P2 at the Roof level, wall pier forces are reported (printed) for locations
    at the top and bottom of the door opening. For graphic representation
    on the model, the forces are plotted at the top and bottom of the pier
    and connected with a straight line. For this reason, pier label shall not be 
    assigned to wall elements when their top or bottom joints are not aligned horizontally. 
    In other words, top and bottom joints must have the same z coordinates, respectivley.

If, for example, you are not interested in either design or output forces for
wall piers P1 and P5 at the Roof level, do not provide wall pier labels for
those area objects.

Wall Spandrel Labeling

In Figure a, the upper wall spandrel label S1 is associated with the Roof level and the lower S1 is associated with the 2nd level. The upper wall

spandrel label S2 is associated with the Roof level, the middle spandrel made up of two area objects labeled S2 is associated with the 2nd level,

and the lowest S2 spandrel is associated with the Base level. Because the wall spandrels are associated with story levels, wall spandrel

labels can be repeated at different levels, as shown in the Figure 3.


  • Wall spandrel forces are output at the left and right ends of wall spandrel elements. 
  • Wall spandrel design is only performed at stations located at the left and right ends of wall spandrel elements. 
    Spandrel label shall not be assigned to wall elements when their left or right joints are not aligned vertically. In 
    other words, left and right joints must have the same x and y coordinates, respectively.
  • Each area object that makes up a part of a wall may be assigned one spandrel label (and one pier label).
  • Multiple wall spandrel labels cannot be assigned to a single area object.Wall spandrel labels are used to identify wall spandrels.
  • After a wall spandrel has been assigned a label and an analysis has been run, forces can be output for the wall spandrel and it can be designed.

  • If you intend to design spandrel S2 that is assigned to the two shells located below and above level 2 as one single beam, assign a new S3 spandrel label and check "Multistory" option in spandrel definition. Spandrel forces will be then integrated from both shells and design of spandrel S3 will be performed based on the full depth.

Tip:

If you need to mesh an existing area object to define a wall spandrel or pier, you can select the area object(s) and use the Edit menu > Mesh Areas command.

Refer to video below for further information: