Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

How are damping values used during response-spectrum analysis?

Extended Question: Damping values are defined in two sections, including the Definition of Response Spectrum Function and the Definition of Response Spectrum Cases. How are these damping values used?

Answer: Structural damping is integral to the response-spectrum curve chosen for analysis. The damping value of this curve should be specified in the Definition of Response Spectrum Cases. During analysis, the response-spectrum curve will be automatically adjusted from the specified damping value to that present in the model.

Structural damping influences response-spectrum analysis in the following ways:

  • It affects the shape of the response-spectrum input curve when modal damping differs from that of the response-spectrum curve. Generally, this is the case when dampers are present in the model.
  • It affects the amount of statistical coupling between the modes used for certain response-spectrum modal combination methods (CQC, GMC).

See Also