You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

Suggestions

  • Height of columns and walls – Slab response and design is dependent upon the height of columns and walls both above and below the slab. We recommend modeling the full height of these vertical systems.
  • Slab-column connections – Standard practice is to model rigid zones at slab-column connections. Since this will reduce the clear span between column locations, vertical slab deflection will also decrease. Another effect is that the magnitude of maximum negative moment (at column locations) will decrease. This is because moment is then taken at the face of the column and not at the centroid. Without modeling rigid zones at slab-column connections, results will be more conservative.