This ETABS formulation is based on the requirements of ACI 318-05 Section 21.6.6. Additional details and an overview are given in the materials available through Help > Documentations and Tutorials > Shear wall design> ACI 318-05 > Wall Pier boundary Element.

hidden-content
Show If
groupeditors

Related Incidents:

  • Incident 46798: Shear Wall Design Importance Factor